Jump to: 🔥 Challenge News ⚡ Intel 🔬 Research Labs 📡 All News →
🇮🇳 India Regulatory Feed

India Regulatory Updates

Live circulars, advisories and policy updates from RBI, SEBI, CERT-In, MeitY, NPCI, and IRDAI — relevant to cybersecurity and data protection compliance.

All regulators RBI 0 SEBI 0 CERT-In 0 MeitY 0 NPCI 0 IRDAI 0
215 updates
CISA
View CSAF Summary Successful exploitation of this vulnerability could crash the module. The device requires a restart to recover. The following versions of Rockwell Automation 1756-ENBT Module are affected: 1756-ENBT module vers:all/* (CVE-2025-10478) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation 1756-ENBT Module Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Critical Manufacturing, Food and Agriculture, Transportation Systems, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-10478 A denial-of-service security issue exists in the Rockwell Automation 1756-ENBT module which is a ControlLogix EtherNet/IP bridge that enables communication between Logix 5000 controllers and Ethernet devices. An attacker could exploit this vulnerability by sending a crafted CIP packet, causing the module to cras
CISA
View CSAF Summary Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk. The following versions of Tycon Systems TPDIN-Monitor-WEB2 (Update A) are affected: TPDIN-Monitor-WEB2 <2.4.5 (CVE-2026-61884, CVE-2026-55985) CVSS Vendor Equipment Vulnerabilities v3 9.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB2 Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-61884 The device ships without HTTP credentials configured, intended for an installer to set them on first use. On firmware 2.4.4 and earlier, a unit left in this unconfigured state serves the web management interface without
CISA
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-77393 In Ignition 8.1.53 and earlier, the Gateway "Create Project Role(s)" setting shipped blank, which permitted any authenticated user to create projects (if they can execute gateway scripts). Ignition 8.1.54 restricts project creation to Designer sessions and no longer relies on this setting. The 8.3 series is not affected. View CVE Details Affected Products Inductive Automation Ignition Vendor:Inductive
CISA
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to take control of a high-privilege terminal during installation and run arbitrary commands. The following versions of OPCFoundation OPC UA LocalDiscoveryServer (LDS) are affected: UA-LDS-Installers <1.04.420 (CVE-2026-77477) CVSS Vendor Equipment Vulnerabilities v3 4.6 OPCFoundation OPCFoundation OPC UA LocalDiscoveryServer (LDS) Execution with Unnecessary Privileges Background Critical Infrastructure Sectors: Chemical, Energy, Food and Agriculture, Water and Wastewater, Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-77477 An attacker can intercept a high-privilege console window launched during installation of the LDS. The attacker must be able to launch an installer with elevated privileges and have access to the keyboard and display while the installation is taking place. View CVE D
CISA
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to perform a man-in-the-middle (MitM) attack, cause a factory reset, wipe credentials, or retrieve sensitive information. The following versions of Tycon Systems TPDIN-Monitor-WEB3 are affected: TPDIN-Monitor-WEB3 <=2.2.9 (CVE-2026-77847, CVE-2026-82712, CVE-2026-82684) CVSS Vendor Equipment Vulnerabilities v3 8.8 Tycon Systems Tycon Systems TPDIN-Monitor-WEB3 Use of Hard-coded Credentials, Cross-Site Request Forgery (CSRF), Missing Authorization Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-77847 Tycon Systems TPDIN-Monitor-WEB3 versions 2.2.9 and prior are vulnerable to a Use of Hard-coded Credential vulnerability. This could allow an attacker to intercept sensitive information or credentials. View CVE Details Affected Produ
CISA
View CSAF Summary Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. The Easergy MiCOM C264 is a modular and compact substation or bay controller, smart RTU and MV one box solution The EcoStruxure Power Automation System Gateway (EPAS=GTW) is a scalable, interoperable, and rugged communication gateway that helps to remotely monitor and operate electrical processes The EcoStruxure Power Automation System User Interface (EPAS-UI) product is an HMI SCADA designed for electrical networks and substations operations. The EcoStruxure Power Automa
CISA
View CSAF Summary Successful exploitation of this vulnerability could give an attacker the ability to run any commands or code of the attacker's choice on a target machine at the logged-in user's permission level. The following versions of Rockwell Automation ControlFLASH are affected: ControlFLASH <=V15.07 (CVE-2026-12663) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation ControlFLASH Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-12663 A security issue exists within ControlFLASH, where the installer grants write permissions to the "Everyone" group on a product installation directory. This could allow arbitrary code execution, resulting in an attacker being given the ability to run any commands or code of the attacker's
CISA
View CSAF Summary Successful exploitation of these vulnerabilities could result in a loss of webserver availability or allow an attacker to inject malicious scripts that will be executed when other users access the affected page. The following versions of Rockwell Automation ArmorStart LT are affected: ArmorStart LT <=v2.001 (CVE-2026-19471, CVE-2026-19472) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation ArmorStart LT Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Allocation of Resources Without Limits or Throttling Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-19471 Multiple stored cross-site scripting security issues exist within ArmorStart LT. Stored XSS occurs when user input is not properly sanitized and is stored on the server, allowing an attacker
CISA
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the computer running the client with elevated privileges. The following versions of IXON VPN Client are affected: VPN Client <1.4.7 (CVE-2026-75925) CVSS Vendor Equipment Vulnerabilities v3 9.6 IXON IXON VPN Client Improper Neutralization of CRLF Sequences ('CRLF Injection') Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Information Technology, Water and Wastewater Countries/Areas Deployed: Worldwide Company Headquarters Location: Netherlands Vulnerabilities Expand All + CVE-2026-75925 Improper Neutralization of CRLF Sequences (CWE-93) in IXON VPN Client before version 1.4.7 allows an attacker to execute commands as root or SYSTEM. Configuration values accepted by the local service are written to a file later consumed by a privileged subprocess, without line-ending sequences being neutralised,
CISA
CISA and the Group of Seven (G7) Cyber Security Working Group released Preparing for the Post-Quantum Era: A Call to Action highlighting the urgent need for organizations and governments to begin transitioning to post-quantum cryptography (PQC) to protect sensitive data, authentication systems, and critical assets from emerging quantum computing threats.   The G7 Cyber Security Working Group’s call to action outlines five priorities for a successful transition to PQC: Raising awareness of quantum risks and the importance of PQC; Developing national strategies that support PQC adoption and integration; Advancing research and development for quantum-safe technologies; Fostering public-private partnerships to share expertise and resources; and Integrating PQC into cybersecurity requirements and procurement processes.  Please share your thoughts! We welcome your feedback. CISA PRODUCT SURVEY
CISA
View CSAF Summary Successful exploitation of this vulnerability could result in memory corruption, a device crash, or a potential remote attack vector without the originating device receiving a CIP error indicating that the request could not be processed. The following versions of Pyramid Solutions NetStaX EtherNet/IP Stack are affected: EtherNet/IP Adapter DLL Kit (EIPA) EtherNet/IP Adapter DLL Kit with CIP Security (EIPA-SECURE) EtherNet/IP Adapter Development Kit (EADK) EtherNet/IP Adapter Development Kit with CIP Security (EADK-SECURE) EtherNet/IP Scanner DLL Kit (EIPS) EtherNet/IP Scanner DLL Kit with CIP Security (EIPS-SECURE) EtherNet/IP Scanner Development Kit (ESDK) EtherNet/IP Scanner Development Kit with CIP Security (ESDK-SECURE) CVSS Vendor Equipment Vulnerabilities v3 9.8 Pyramid Solutions Pyramid Solutions NetStaX EtherNet/IP Stack Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater,
SANS ISC
[This is a Guest Diary by Frank Igbokwe, an ISC intern as part of the SANS.edu BACS program]&#xd;
SANS ISC
(c) SANS Internet Storm Center. https://isc.sans.edu Creative Commons Attribution-Noncommercial 3.0 United States License.
CISA
Developed by CISA, the Federal Bureau of Investigation, and international partners, this guidance describes how organizations can plan and execute clear, timely, accurate, and audience-appropriate communications during IT and operational technology (OT) outages. Whether caused by cyber threat actors, human error, equipment failure, or natural hazards, service outages can create disruption and societal panic even without speculation from end users and the public as added factors. Outages at one organization may cascade across interconnected systems, increasing uncertainty and alarm. The guidance emphasizes clarity, accountability, and transparency as core principles and details key elements of effective crisis messaging to inform affected stakeholders and the public while aligning with legal requirements, operational security, law enforcement, and containment efforts.  CISA’s CI Fortify initiative provides information and resources that help critical infrastructure organizations prep
CISA
CISA has added seven new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation.   CVE-2026-9586 Sangoma Switchvox SQL Injection Vulnerability  CVE-2026-48710 Kludex Starlette HTTP Request/Response Smuggling Vulnerability  CVE-2026-49869 Kestra OSS OS Command Injection Vulnerability  CVE-2026-59822 BerriAI LiteLLM Improper Authentication Vulnerability  CVE-2026-82329 JFrog Artifactory Improper Authentication Vulnerability  CVE-2026-83548 SonicWall SMA1000 Appliances Server-Side Request Forgery Vulnerability  CVE-2026-83549 SonicWall SMA1000 Appliances OS Command Injection Vulnerability  These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.  Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Br
SANS ISC
(c) SANS Internet Storm Center. https://isc.sans.edu Creative Commons Attribution-Noncommercial 3.0 United States License.
CISA
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the affected product. The following versions of Rockwell Automation RSLinx Classic are affected: RSLinx Classic <=4.50 (CVE-2026-9621, CVE-2026-9622, CVE-2026-9624, CVE-2026-9625) CVSS Vendor Equipment Vulnerabilities v3 8.6 Rockwell Automation Rockwell Automation RSLinx Classic Integer Overflow or Wraparound, Integer Underflow (Wrap or Wraparound), Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9621 A denial-of-service security issue exists within RSLinx Classic. The security issue stems from improper handling of a malformed packet. A crafted CIP packet can cause the RSLinx Classic service to crash, requiring a restart of the se
CISA
View CSAF Summary Successful exploitation of these vulnerabilities could crash the device being accessed; an out-of-bounds write condition may allow remote code execution. The following versions of Rockwell Automation Historian ME are affected: Series B 5.202 (CVE-2025-12768, CVE-2026-12661) Series C 7.101 (CVE-2025-12768, CVE-2026-12661) CVSS Vendor Equipment Vulnerabilities v3 8 Rockwell Automation Rockwell Automation Historian ME Out-of-bounds Write, Stack-based Buffer Overflow Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Food and Agriculture, Healthcare and Public Health, Water and Wastewater Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2025-12768 A security issue exists within FactoryTalk® Historian Machine Edition. An attacker with low-level authentication could exploit this vulnerability to achieveremote code execution on the affected device. View CV
CISA
View CSAF Summary The following versions of Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix are affected: ControlLogix 5580 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) GuardLogix 5580 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) CompactLogix 5380 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) Compact GuardLogix 5380 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) CompactLogix 5480 <34.015, <35.014, <36.013, <37.011 (CVE-2021-42260, CVE-2021-42260, CVE-2021-42260, CVE-2021-42260) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation ControlLogix, CompactLogix, CompactLogix 5480, GuardLogix, Compact GuardLogix Loop with Unreachable Exit Condition ('Infinite Loop') Background Critic
CISA
View CSAF Summary The following versions of Rockwell Automation Logix Platform are affected: ControlLogix 5580 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637) CompactLogix 5380 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637) GuardLogix 5580 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637) Compact GuardLogix 5380 <=V33, V34.011-V34.014, V35.011-V35.013, V36.011-V36.012 (CVE-2026-9637, CVE-2026-9637, CVE-2026-9637, CVE-2026-9637) CVSS Vendor Equipment Vulnerabilities v3 7.5 Rockwell Automation Rockwell Automation Logix Platform Improper Restriction of Operations within the Bounds of a Memory Buffer Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expan
CISA
View CSAF Summary Successful exploitation of these vulnerabilities could allow for an attacker to escalate and execute processes with administrator privileges. The following versions of Rockwell Automation Redundancy Module Configuration Tool are affected: Redundancy Module Configuration Tool 10.00.00 (CVE-2026-9633) Redundancy Module Configuration Tool >=9.00.00|<=10.00.00 (CVE-2026-9634) CVSS Vendor Equipment Vulnerabilities v3 7.3 Rockwell Automation Rockwell Automation Redundancy Module Configuration Tool Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-9633 A security issue exists within the Redundancy Module Configuration Tool. The RM3ConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non administrato
CISA
View CSAF Summary The following versions of Rockwell Automation FactoryTalk Activation Manager are affected: FactoryTalk Activation Manager V5.02_and_below (CVE-2026-16675) CVSS Vendor Equipment Vulnerabilities v3 7.8 Rockwell Automation Rockwell Automation FactoryTalk Activation Manager Improper Restriction of Excessive Authentication Attempts Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-16675 A privilege escalation vulnerability exists within FactoryTalk Activation Manager. The vulnerability stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resou
SANS ISC
(c) SANS Internet Storm Center. https://isc.sans.edu Creative Commons Attribution-Noncommercial 3.0 United States License.
SANS ISC
One of my internet-exposed inference honeypots was discovered, relabeled with sought-after model names, and incorporated into infrastructure apparently used to provide "free" LLM backends. It then received a real coding-agent session &&#x23;x26;&#x23;xe2;&&#x23;x26;&#x23;x80;&&#x23;x26;&#x23;x94; history, filesystem output, working paths, and the agent&&#x23;x26;&#x23;39;s local tool manifest. The honeypot did not request or cause any tool execution; what the request exposed is what a malicious operator in that position could do.&#xd;
CISA
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation.   CVE-2026-81578 PaperCut NG/MF Missing Authentication for Critical Function Vulnerability  CVE-2026-82078 PaperCut NG/MF Unsafe Reflection Vulnerability  These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.  Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for l
SANS ISC
(c) SANS Internet Storm Center. https://isc.sans.edu Creative Commons Attribution-Noncommercial 3.0 United States License.
SANS ISC
YARA-X&&#x23;x26;&#x23;39;s 1.20.0 release brings 14 improvements and 13 bugfixes.&#xd;
SANS ISC
During my last FOR610 session, a student asked me if I had some statistics in mind about the compilers used to generate malicious PE files? A couple of months ago, I shared some stats about the trend in 64bits VS. 32bits malware[1]. Can we go a bit further? I (vibe-)coded a Python script based on the pefile library[2] to extract some info from the PE headers. Indeed, the PE file format contains a lot of metadata! They can be accessed using a lot of tools, like Detect It Easy:&#xd;
SANS ISC
(c) SANS Internet Storm Center. https://isc.sans.edu Creative Commons Attribution-Noncommercial 3.0 United States License.

Sources

RBI 0
SEBI 0
CERT-In 0
MeitY 0
NPCI 0
IRDAI 0