Successful exploitation of this vulnerability could allow an attacker to gain full system control and misuse it to access or manipulate connected networks and resources.
The following versions of Toptech Systems RCU II+ and Multiload II+ are affected:
RCU II+ <2025-11-24 (CVE-2026-12562)
Multiload II+ <2025-11-24 (CVE-2026-12562)
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.8
Toptech Systems
Toptech Systems RCU II+ and Multiload II+
Missing Authentication for Critical Function
Background
Critical Infrastructure Sectors: Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2026-12562
The RCU II+ and Multiload II+ are vulnerable to an unauthenticated service that exposes a debug interface granting full root-level access to the embedded system. This vulnerability stems from a network-accessible port running a Target Communications Framework (TCF) service that does not require any
View CSAF
Summary
Successful exploitation of this vulnerability could allow a malicious user the ability to deliver malicious firmware that can update and gain full control of the controller.
The following versions of Watchfire Controller Software are affected:
BC550 12.30 (CVE-2026-5846)
BC750 11.33 (CVE-2026-5846)
BC750 12.35 (CVE-2026-5846)
BC760 12.38 (CVE-2026-5846)
BC760 13.00 (CVE-2026-5846)
BC760DC 12.39 (CVE-2026-5846)
CVSS
Vendor
Equipment
Vulnerabilities
v3 5.7
Watchfire
Watchfire Controller Software
Use of Hard-coded Cryptographic Key
Background
Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Healthcare and Public Health, Financial Services
Countries/Areas Deployed: United States, Dominican Republic, Canada, Peru, El Salvador
Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2026-5846
The affected product contains self-signed hard-coded RSA private keys and corresponding X.509 certificates used
CISA is currently observing a significant increase in cyber threat actors targeting programmable logic controllers (PLCs) in the Water and Wastewater Systems (WWS) Sector. CISA urges critical infrastructure owners, operators, and integrators to remove publicly exposed PLCs and other operational technology (OT) from the internet as soon as possible. Threat actors targeting exposed PLCs have modified passwords to lock out operators and disconnected the PLCs by changing their IP addresses. This activity has resulted in boil water notices and sustained manual operations.
These threat actors are targeting water entities of all sizes. Even water organizations with mature cybersecurity processes should validate their external connections, as this targeting activity includes cellular modems installed by operators, vendors, or system integrators that may not be documented or included in routine attack surface scans. OT assets exposed to the internet have an increased risk of defacement, c
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker to upload malicious files, execute stored cross-site scripting attacks, or inject arbitrary HTML content.
The following versions of Johnson Controls OpenBlue Employee are affected:
OpenBlue Employee (FMS Employee) <=V2025.3.1 (CVE-2026-21662, CVE-2026-34495, CVE-2026-34497)
CVSS
Vendor
Equipment
Vulnerabilities
v3 2.4
Johnson Controls Inc.
Johnson Controls OpenBlue Employee
Unrestricted Upload of File with Dangerous Type, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Background
Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Ireland
Vulnerabilities
Expand All +
CVE-2026-21662
The application doe
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the device.
The following versions of MZ Automation GmbH libiec61850 are affected:
libiec61850 <1.6.2 (CVE-2026-66720, CVE-2026-66369, CVE-2026-63550, CVE-2026-65421, CVE-2026-66364, CVE-2026-66349, CVE-2026-56758, CVE-2026-66360)
CVSS
Vendor
Equipment
Vulnerabilities
v3 7.5
MZ Automation GmbH
MZ Automation GmbH libiec61850
Out-of-bounds Read
Background
Critical Infrastructure Sectors: Energy
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-66720
The GOOSE subscriber component improperly validates the UTC timestamp field in unauthenticated IEC 61850 GOOSE (EtherType 0x88B8) Layer-2 multicast messages. A specially crafted GOOSE frame containing an undersized timestamp field can trigger a heap out-of-bounds read during message processing, causing the process to crash and
View CSAF
Summary
Successful exploitation of these vulnerabilities could crash the device being accessed.
The following versions of MZ Automation lib60870 are affected:
lib60870 2.4.0 (CVE-2026-61893, CVE-2026-63033)
CVSS
Vendor
Equipment
Vulnerabilities
v3 6.5
MZ Automation GmbH
MZ Automation lib60870
Out-of-bounds Read
Background
Critical Infrastructure Sectors: Energy, Water and Wastewater, Critical Manufacturing, Chemical
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-61893
A crafted IEC 60870-5-104 I-frame with TypeID 104 (C_TS_NA_1) and an inflated object count causes TestCommand_getFromBuffer to read one byte past the end of the heap-allocated message buffer.
View CVE Details
Affected Products
MZ Automation lib60870
Vendor:MZ Automation GmbH
Product Version:MZ Automation GmbH lib60870: 2.4.0
Product Status:known_affected
Remediations
MitigationMZ Automation recommends users update to versio
View CSAF
Summary
Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition.
The following versions of Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module are affected:
ControlLogix 5580 >=V36|<=V37 (CVE-2026-9636)
CompactLogix 5380 >=V36|<=V37 (CVE-2026-9636)
GuardLogix 5580 >=V36|<=V37 (CVE-2026-9636)
Compact GuardLogix 5380 >=V36|<=V37 (CVE-2026-9636)
1756-EN4TR V6.001 (CVE-2026-9636)
1756-EN4TR V7.001 (CVE-2026-9636)
CVSS
Vendor
Equipment
Vulnerabilities
v3 5.9
Rockwell Automation
Rockwell Automation CompactLogix 5380 ControlLogix 5580 / 1756-EN4TR Communications Module
Improper Check for Certificate Revocation
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2026-9636
A security issue exists within CompactLogix 5380, Co
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial of service, or potentially execute arbitrary code.
The following versions of o6 Automation open62541 are affected:
open62541 on Windows and Linux >=from_1.3.0|<=1.3.17 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559)
open62541 on Windows and Linux >=from_1.4.0|<=1.4.16 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559)
open62541 on Windows and Linux >=from_1.5.0|<=1.5.4 (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559)
open62541 on Windows and Linux master (CVE-2026-63362, CVE-2026-65423, CVE-2026-63035, CVE-2026-63559)
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.8
o6 Automation GmbH
o6 Automation open62541
Integer Underflow (Wrap or Wraparound), Integer Overflow or Wraparound, Use After Free
Background
Critical Infrastructure Sectors: Critical Manufacturing, Energy, Tran
CISA, the National Security Agency, the Federal Bureau of Investigation, and international partners released joint guidance, 2026 Minimum Elements for a Software Bill of Materials (SBOM), that updates and replaces the minimum elements for an SBOM published by the National Telecommunications and Information Administration (NTIA) in 2021. The new guidance incorporates stakeholder feedback from a 2025 public comment period and reflects current SBOM tools and needs while preserving the core principles of the original NTIA document.
An SBOM serves as an “ingredients list” for software and is a key building block of software security and supply chain risk management. Organizations can use SBOM data to better understand the makeup of their software components and supply chains and make more risk-informed decisions. Minimum elements for an SBOM describe the baseline technologies and practices that an SBOM should include.
While the minimum elements for an SBOM apply to all s
CISA has added one new vulnerability to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation.
CVE-2026-20316 Cisco Secure Firewall Management Center Use of Hard-coded Password Vulnerability
This type of vulnerability is a frequent attack vector for malicious cyber actors and poses significant risks to the federal enterprise.
Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation, while deferring action for lower-risk vulnerabilities. BOD 26-04 further establishes basic exp
Progress is being made, but too many network devices still remain difficult to investigate after compromise
View CSAF
Summary
ABB has been contacted by a researcher who identified a vulnerability in one of its products. ABB has been contacted by a researcher who identified a vulnerability in one of its products. The vulnerability report has been shared in responsible disclosure. An attacker who successfully exploited this vulnerability could cause the product to become unusable. ABB confirms the vulnerability but at the same time acknowledges that the issue affects exclusively classic KNX devices that are not supporting the latest KNX Secure standard. Due to a lack of security in legacy KNX devices, the issue cannot be resolved via a software change. In order to actively exploit this vulnerability, an attacker requires physical access to the bus, the affected device is connected to. ABB has no plans of corrective measures.
The following versions of ABB KNX Update Tool are affected:
KNX Update Tool (ABB) <=2.0.175 (CVE-2026-12705)
KNX Update Tool (BJE) <=2.0.175 (CVE-2026-12705)
C
CI Fortify – Advice for isolating vital systems
CI Fortify – Advice for isolating vital systems (PDF)CISA and the Australian Signals Directorate’s Australian Cyber Security Centre (ASD’s ACSC), in collaboration with the Federal Bureau of Investigation and international partners, released joint guidance CI Fortify – Advice for isolating vital systems. This guidance contains practical steps for critical infrastructure (CI) organizations to isolate vital operational technology and enabling systems from all other networks in the event of disruption or crisis and operate in isolation for an extended period. Developed to address escalating cyber threats, the guidance outlines key steps for identifying critical systems, mapping connections, and implementing effective separation points. By following these recommendations, organizations can enhance their resilience, minimize disruption, and maintain essential services during cyber incidents or geopolitical crises.
View CSAF
Summary
Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.6 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected:
SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.6 (CVE-2021-41617, CVE-2023-28531, CVE-2023-51384, CVE-2023-52927, CVE-2024-26783, CVE-2024-27056, CVE-2024-28956, CVE-2024-36903, CVE-2024-36927, CVE-2024-42079, CVE-2024-46786, CVE-2024-47736, CVE-2024-47809, CVE-2024-49968, CVE-2024-49994, CVE-2024-49998, CVE-2024-50014, CVE-2024-50063, CVE-2024-50164, CVE-2024-50298, CVE-2024-53124, CVE-2024-53170, CVE-2024-54458, CVE-2024-56631, CVE-2024-56703, CVE-2024-56719, CVE-2024-57917, CVE-2024-57924, CVE-2024-57973, CVE-2024-57977, CVE-2024-57979
View CSAF
Summary
OpenSSL has published a stack based buffer overflow vulnerability that allows a remote attacker to cause a denial of service (DoS) or potentially allow for remote code execution. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available.
The following versions of Siemens Desigo CC are affected:
Desigo CC family V7 vers:all/* (CVE-2025-15467)
Desigo CC family V8 vers:all/* (CVE-2025-15467)
Desigo CC family V9 vers:intdot/<9.0.1 (CVE-2025-15467)
CVSS
Vendor
Equipment
Vulnerabilities
v3 9.8
Siemens
Siemens Desigo CC
Out-of-bounds Write
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2025-15467
Issue summary: Parsing CMS AuthEnvelopedData messag
View CSAF
Summary
Successful exploitation of this vulnerability could allow an unauthorized actor to access functions or backend services.
The following versions of igloohome Smart Lock Mobile Application are affected:
Smart Lock Mobile Application (Android) 3.2.3 (CVE-2026-16581)
CVSS
Vendor
Equipment
Vulnerabilities
v3 5.3
igloohome
igloohome Smart Lock Mobile Application
Inclusion of Sensitive Information in Source Code
Background
Critical Infrastructure Sectors: Commercial Facilities
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Singapore
Vulnerabilities
Expand All +
CVE-2026-16581
In igloohome Smart Lock Mobile App versions 3.2.3 and prior, an Inclusion of Sensitive Information in Source Code vulnerability could allow an unauthorized actor to access functions or backend services that were not sufficiently protected by authentication controls.
View CVE Details
Affected Products
igloohome Smart Lock Mobile Application
Vendor:igloohome
Produ
View CSAF
Summary
SIMATIC S7-PLCSIM Advanced contains a vulnerability that could allow an attacker to cause a denial of service condition. Siemens is preparing fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.
The following versions of Siemens SIMATIC S7-PLCSIM Advanced are affected:
SIMATIC S7-PLCSIM Advanced vers:all/* (CVE-2026-54429)
CVSS
Vendor
Equipment
Vulnerabilities
v3 7.4
Siemens
Siemens SIMATIC S7-PLCSIM Advanced
Allocation of Resources Without Limits or Throttling
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-54429
Affected devices do not properly handle high-volume multicast network traffic, which can exhaust available memory resources in the affected application. This could allow an unauthenticated attacker on the local network segment to cause a denial-of-servic
View CSAF
Summary
Mendix documentation for access rules does not adequately describe the special behavior of the System.User entity, leaving developers without sufficient guidance to configure access rules securely. This documentation gap may lead application developers to unknowingly apply overly permissive access rules to System.User, resulting in unintended exposure of sensitive user data or privilege escalation within deployed Mendix applications. A common misconfiguration identified is with the anonymous user role with a System.User entity to gain access to all stored records, even though no access rights are explicitly configured on that role. Siemens recommends Mendix developers to review their access rules based on updated documentation.
The following versions of Siemens Mendix Runtime are affected:
Mendix Runtime vers:all/* (CVE-2026-7891)
CVSS
Vendor
Equipment
Vulnerabilities
v3 9.1
Siemens
Siemens Mendix Runtime
Insecure Inherited Permissions
Background
Critic
View CSAF
Summary
Successful exploitation of this vulnerability could allow attackers to rapidly guess passwords and gain unauthorized system access.
The following versions of MikroTik RouterOS and Cloud Hosted Router are affected:
RouterOS vers:all/* (CVE-2026-16347)
Cloud Hosted Router vers:all/* (CVE-2026-16347)
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.8
MikroTik
MikroTik RouterOS and Cloud Hosted Router
Improper Restriction of Excessive Authentication Attempts
Background
Critical Infrastructure Sectors: Information Technology, Commercial Facilities
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Latvia
Vulnerabilities
Expand All +
CVE-2026-16347
MikroTik RouterOS contains a weakness in its API authentication handling that lacks effective safeguards against excessive login attempts. The system does not enforce meaningful rate-limiting, account lockout, or source-based restrictions, allowing repeated authentication failures to proceed without
A highly disruptive incident can feel overwhelming. New guidance provides a framework for response and recovery.
CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities (KEV) Catalog, based on evidence of active exploitation.
CVE-2025-68686 Fortinet FortiOS Exposure of Sensitive Information to an Unauthorized Actor Vulnerability
CVE-2026-16812 Arista VeloCloud Orchestrator On-Prem OS Command Injection Vulnerability
These types of vulnerabilities are a frequent attack vector for malicious cyber actors and pose significant risks to the federal enterprise.
Binding Operational Directive (BOD) 26-04: Prioritizing Security Updates Based on Risk establishes vulnerability management requirements for Federal Civilian Executive Branch (FCEB) agencies. BOD 26-04 reinforces the importance of the KEV Catalog and requires federal agencies to prioritize rapid remediation of high-risk vulnerabilities, specifically those identified by Common Vulnerabilities and Exposures (CVEs) listed in CISA’s KEV Catalog on publicly exposed assets that grant total control of the asset post-exploitation
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow a non-privileged user to escalate privileges or view the credentials of other users.
The following versions of Weintek cMT3092X are affected:
cMT3092X firmware <20210218
EasyWeb <v2.1.20
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.8
Weintek
Weintek cMT3092X
Reliance on Cookies without Validation and Integrity Checking in a Security Decision, Incorrect Permission Assignment for Critical Resource, Plaintext Storage of a Password, Incorrect User Management
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Taiwan
Vulnerabilities
Expand All +
CVE-2026-60134
Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges.
View CVE Details
Affected Products
Weintek cMT3092X
Vendor:Weintek
Product Version:Weintek cMT3092X firmware: <20210218, Weintek EasyWeb: <v2.
View CSAF
Summary
Successful exploitation of this vulnerability could allow an authenticated attacker to write arbitrary files to restricted system directories outside of the application's intended directory.
The following versions of Rockwell Automation ThinManager are affected:
ThinManager >=13.0.0|<13.0.7, >=13.1.0|<13.1.5, >=13.2.0|<13.2.4, >=14.0.0|<14.0.2
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.1
Rockwell Automation
Rockwell Automation ThinManager
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Background
Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Food and Agriculture, Water and Wastewater
Countries/Areas Deployed: Worldwide
Company Headquarters Location: United States
Vulnerabilities
Expand All +
CVE-2026-11917
A path traversal security issue exists within Rockwell Automation ThinManager software due to improper limitation of file save operations within the API. An authe
View CSAF
Summary
Successful exploitation of this vulnerability could cause the parsing process to crash, which will cause a denial of service.
The following versions of MZ Automation lib60870 are affected:
lib60870 <=2.4.0
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.2
MZ Automation
MZ Automation lib60870
Out-of-bounds Read
Background
Critical Infrastructure Sectors: Chemical, Energy, Water and Wastewater
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-16002
The affected product is vulnerable to an Out-of-bounds read, which may allow an attacker to crash the parsing process and cause a denial of service.
View CVE Details
Affected Products
MZ Automation lib60870
Vendor:MZ Automation
Product Version:MZ Automation lib60870: <=2.4.0
Product Status:known_affected
Remediations
Vendor fixMZ automation recommends users update to version 2.4.1 or later. Documentation can be found at https://github.com/
View CSAF
Summary
Successful exploitation of this vulnerability could result in an attacker obtaining confidential information from the device.
The following versions of Johnson Controls XAAP Android are affected:
XAAP Android <1.53
CVSS
Vendor
Equipment
Vulnerabilities
v3 3.3
Johnson Controls
Johnson Controls XAAP Android
Cleartext Storage of Sensitive Information
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Ireland
Vulnerabilities
Expand All +
CVE-2026-34490
A cleartext storage weakness exists in the Fire Solutions Android application, which stores application data locally on the device without encryption. An attacker with physical access to the device and one able to compromise the device through a separate, unrelated flaw, could potentially read this data in plaintext. Exploitation does not require network access and is limited to the local device environment.
View CVE De
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker with network access to achieve remote code execution.
The following versions of Johnson Controls C-CURE 9000 and Victor application server are affected:
C-CURE 9000 and victor <=v2.90_v3.0
victor Web <=v7.1
CVSS
Vendor
Equipment
Vulnerabilities
v3 9.6
Johnson Controls
Johnson Controls C-CURE 9000 and Victor application server
Server-Side Request Forgery (SSRF), Execution with Unnecessary Privileges
Background
Critical Infrastructure Sectors: Critical Manufacturing
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Ireland
Vulnerabilities
Expand All +
CVE-2026-21655
Under certain circumstances, successful exploitation of this vulnerability could allow an unauthenticated attacker on the adjacent network to achieve arbitrary code execution on the C-CURE 9000 or victor application server, as well as connected clients (e.g., workstations of physica
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an attacker with access to the IT network to manipulate industrial control devices without requiring physical access, specialized insider knowledge, or advanced tooling.
The following versions of Panduit IntraVUE are affected:
IntraVUE <=3.2.1a14
CVSS
Vendor
Equipment
Vulnerabilities
v3 10
Pronetiqs
Panduit IntraVUE
Plaintext Storage of a Password, Unintended Proxy or Intermediary ('Confused Deputy'), Exposure of Sensitive System Information to an Unauthorized Control Sphere, Inadequate Encryption Strength
Background
Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology, Water and Wastewater
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Netherlands
Vulnerabilities
Expand All +
CVE-2026-40430
Pronetiqs IntraVUE Versions 3.2.1a14 and prior have a plaintext storage of a password vulnerability that could expose cleartext credenti
GCHQ’s National Cyber Security Centre and international partners issue warning as ‘LAUNDRY BEAR’ cyber threat group exposed for targeted phishing campaign
View CSAF
Summary
Successful exploitation of these vulnerabilities could allow an unauthenticated network-adjacent attacker to crash critical IEC 61850 services or execute arbitrary code, disrupting or compromising protection, visibility, and control functions.
The following versions of MZ Automation libIEC61850 are affected:
libIEC61850 >=v1.0.0|<=v1.6.1
CVSS
Vendor
Equipment
Vulnerabilities
v3 8.1
MZ Automation
MZ Automation libIEC61850
Stack-based Buffer Overflow, Heap-based Buffer Overflow, Improper Handling of Syntactically Invalid Structure, NULL Pointer Dereference
Background
Critical Infrastructure Sectors: Critical Manufacturing, Energy, Transportation Systems
Countries/Areas Deployed: Worldwide
Company Headquarters Location: Germany
Vulnerabilities
Expand All +
CVE-2026-50039
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to cause a memory corruption via a ReadRequest.
View CVE Details
Affected Products
No organisation can navigate the migration alone; key takeaways from our first PQC migration workshop.
Sources
RBI
0
SEBI
0
CERT-In
0
MeitY
0
NPCI
0
IRDAI
0